Direct-current Static Watt-hour Meter AEM11-PS
- YEAR: 2010
AEM11-PS is a direct-current static watt-hour meter for indirect connection designed to measure electric energy in direct-current traction framework. It is connected into the measurement circuit through the external galvanically devided direct-current converters of voltage and current. The meter conforms the STN EN 50463: Traction applications norm. Measurement of energy on locomotive vehicles.
Technical parameters
SUPPLY VOLTAGE |
= 24V ± 5 % |
MAXIMUM CONSUMPTION | 100 mA |
VOLTAGE INPUT CURRENT RATING IUN | 36 mA = |
- OVERLOAD CAPACITY |
50 % |
- INPUT IMPEDANCE | 10 Ω |
CURRENT INPUT CURRENT RATING IIN |
150 mA = |
- MAXIMUM INPUT CURRENT IIMAX |
375 mA = |
- INPUT IMPEDANCE |
10 Ω |
NOMINAL INPUT VOLTAGE OF EXTERNAL CONVERTER UN |
3 024 V = |
- OVERLOAD CAPACITY |
50 % |
NOMINAL INPUT CURRENT OF EXTERNAL CONVERTER IN |
300 A = |
MAXIMUM INPUT CURRENT OF EXTERNAL CONVERTER IMAX |
750 A = |
ACCURACY CLASS |
1 |
IN THE RANGE OF INPUT CURRENT |
5 % In – Imax |
AT INPUT VOLTAGE |
90 – 110 % Un |
MEASUREMENT TEMPERATURE RANGE |
-25 - +70 °C |
STARTING CURRENT |
< 0,004 In |
OPTICAL IMPULSE OUTPUT |
10 imp./kWh |
PARAMETERS MEASURED |
active energy, active power, voltage, current |
RECORDED PARAMETER |
active energy consumption |
RECORDING PERIOD |
configurable 1 – 99 minutes, stand. 15 min. |
MEMORY CAPACITY |
min. 1 year at 15 min. recording |
COMMUNICATION OUTPUT INTERFACE |
RS-485 |
OUTPUT PROTOCOL |
according to STN EN 62056-21 norm |
COMMUNICATION SPEED |
configurable, 4 800 Bd standard |
DIMENSIONS |
w/h/d 75 x 65 x 100 mm |