Finished Projects › Projects by Activity Areas › Industrial Electronics › AIN16 - device for voltage indication
AIN16 - device for voltage indication
- CLIENT: IFT InForm Technologies
Device for indication of 600 VDC in distribution points of electricity and fuseboxes with two output contacts.
Technical parameters
SUPPLY VOLTAGE | +10 to +30 VDC |
SUPPLY CURRENT | max. 50 mA / 10 VDC, 20mA / 30 VDC |
BUILT-IN CURRENT AND OVER-VOLTAGE PROTECTION | Reversible fuse 100 mA |
BI-POLAR VOLTAGE INPUT VIN1 AND VIN2 |
Nom. 600 VDC, max. 1000 VDC CAT III |
VOLTAGE INDICATION LEVEL | 300 VDC ± 10% |
OUTPUT – TWO CONTACTS |
K1 – switching contact (on), K2- switching contact (off) |
MAXIMAL SWITCHING LOAD |
0,5A at 125 VAC, 1A at 24 VDC |
ISOLATION VOLTAGE, INPUT - OUTPUT |
12 kV according to UL1577 |
DISTANCE OF STRENGHTENED ISOLATION, INPUT – OUTPUT 14,3 mm |
max. 1000V, CAT III, according to STN EN 61010-1 |
PLASTIC BOX WITH 35 mm DIN BAR CONNECTION |
dimensions 98 x 57 x 17,5 mm |
PROTECTION |
IP20 |
WORKING TEMPERATURE RANGE |
-25 to +70 °C |